NDP-50-E/500-E series
Simple Structure and Easy Maintenance!
This model has a built-in high-frequency transmitting proximity sensor.
This diaphragm pump operates by detecting a sensor and controlling the switching of a solenoid valve.
Fully self-suction type that can pump out fluid efficiently, with no pump-priming required.
The NDP-50-E series has a nominal diameter of 2" (50 mm) and a maximum flow rate of approximately 500 L/min.
The maximum size solid is 8 mm or less.
*The NDP-E series Is Not Explosion-proof. This Series Is Built-to-order, So Be Sure to Confirm the Delivery Date.
■ Main Applications
Mold Release Agent/Application of Coating Material/Transfer of Inks and Pigments/Circulation and Spraying of Mold Release Agent, Pumping Out Factory Wastewater and Waste Oil/Supply of Paint to Roll Coater/Transfer of Clay and Glazes/Supplying Oil, Coolant Fluid, Paint, Etc.
Features
■ Sensor Control Model with Built-in Proximity Sensor that Transmits High Frequencies
The sensor built into the pump detects the stroke end, and the pump controller switches the solenoid valve to operate the pump.
◆ Sensor Control “Proximity Sensor”
| Sensor Control = Stable Reciprocating Motion |
|
A proximity sensor detects the stroke end of the diaphragm, and the pump controller receiving the sensor signal controls the switching of the center exhaust type 3-position 5-port solenoid valve. |
|
Optional Counter Connection Enables Stroke Management |
|
By counting the number of times the center rod has moved, it is possible to determine when parts need to be replaced. |
Specifications
Click on the model number to download the product datasheet (specifications, dimensions, and performance curves).
| Body Material | A: Aluminum (ADC12/AC4C-T6) |
S: Stainless Steel (SCS14) |
F: Cast Iron (FC250) |
P: GF Polypropylene (PP-GF) |
500-E series S: Stainless Steel (SCS14) |
||||
| Diaphragm Material | |||||||||
| C: Polychloloprene (CR) | NDP-50BAC-E (853181) |
NDP-50BSC-E (853188) |
NDP-50BFC-E (853195) |
NDP-50BPC-E (853202) |
NDP-500BSC-E (855435) |
||||
| N: Buna N (NBR) | NDP-50BAN-E (853177) |
NDP-50BSN-E (853184) |
NDP-50BFN-E (853191) |
NDP-50BPN-E (853198) |
NDP-500BSN-E (855436) |
||||
| E: Ethylene Propylene Diene Monomer (EPDM) | NDP-50BAE-E (853182) |
NDP-50BSE-E (853189) |
NDP-50BFE-E (853196) |
NDP-50BPE-E (853203) |
NDP-500BSE-E (855437) |
||||
| V: Fluorelastomer (FKM) | NDP-50BAV-E (853180) |
NDP-50BSV-E (853187) |
NDP-50BFV-E (853194) |
NDP-50BPV-E (853201) |
NDP-500BSV-E (855438) |
||||
| T: Polytetrafluoroethylene (PTFE) | NDP-50BAT-E (853179) |
NDP-50BST-E (853186) |
NDP-50BFT-E (853193) |
NDP-50BPT-E (853200) |
NDP-500BST-E (855439) |
||||
| H: Thermoplastic Polyester Elastomer (TPEE) | NDP-50BAH-E (853178) |
NDP-50BSH-E (853185) |
NDP-50BFH-E (853192) |
NDP-50BPH-E (853199) |
NDP-500BSH-E (855440) |
||||
| S: Thermoplastic Olefinic Elastomer (TPO) | NDP-50BAS-E (853183) |
NDP-50BSS-E (853190) |
NDP-50BFS-E (853197) |
NDP-50BPS-E (853204) |
NDP-500BSS-E (855441) |
||||
| Wetted Parts Material | |||||||||
| Ball Valve | Same as the diaphragm material | Same as the diaphragm material | |||||||
| Valve Seat | NDP-50BAT-E: A5056 Others: Same as the diaphragm material |
NDP-50BST-E: SUS316 Others: Same as the diaphragm material |
NDP-50BFT-E: SUS316 Others: Same as the diaphragm material |
PP | NDP-500BST-E: SUS316 Others: Same as the diaphragm material |
||||
| Valve Stopper | Same as the body material (integrated type) | Same as the body material (integrated type) | |||||||
| Center Disk | A5056 | SUS316 | SS400 | PP-GF SCS13 (Insert material) |
SUS316 | ||||
| Specifications | |||||||||
| Nominal Diameter | 2"(50 mm) | 2"(50 mm) | |||||||
| Material Connection | Suction Port | JIS flange 10K 50A equivalent |
Rc 2 | JIS flange 10K 50A equivalent |
JIS flange 10K 50A equivalent |
||||
| Discharge Port | |||||||||
| Air Connection | Supply Port | Rc 3/4 x 2 (Shared supply and exhaust port x 2) *1 | Rc 3/4 x 2 (Shared supply and exhaust port x 2) *1 | ||||||
| Exhaust Port | |||||||||
| Air Supply Pressure | 0.2~0.7 MPa *2 | 0.2~0.7 MPa *2 | |||||||
| Maximum Discharge Pressure | 0.7 MPa | 0.7 MPa | |||||||
| Water Discharge/Cycle | Fluorine resin diaphragm: 2.1 L Other diaphragm: 4.3 L *3 | Fluorine resin diaphragm: 2.5 L Other diaphragm: 5.0 L *3 | |||||||
| Maximum Flow Rate | Fluorine resin diaphragm: 430 L/min *4 Other diaphragm: 500 L/min *4 |
Fluorine resin diaphragm: 360 L/min *4 Other diaphragm: 490 L/min *4 |
Fluorine resin diaphragm: 420 L/min *4 Other diaphragm: 580 L/min *4 |
||||||
| Maximum Air Consumption | Fluorine resin diaphragm: 4500 L/min Other diaphragm: 4000 L/min | Fluorine resin diaphragm: 4600 L/min Other diaphragm: 4000 L/min |
|||||||
| Maximum Size Solid | Maximum 8 mm | Maximum 8 mm | |||||||
| Suction Head Lift | NDP-50B○T-E: 3 m Others: 5 m | NDP-500BST-E: 3 m Others: 5.5 m |
|||||||
| Net Weight | 36.0 kg | 53.0 kg | 64.0 kg | 34.0 kg | NDP-500BST-E: 56.9 kg Others: 61.2 kg |
||||
*1 The pipe length from the air supply valve (solenoid valve, etc.) to the pump shall be 1.5 m or less. If piping from the exhaust port of the air supply valve to another location, the pipe length to the end of the exhaust port shall be 5 m or less.
*2 The maximum supply air pressure for a type with a resin-made pump body will depend on the liquid temperature.
*3 The water discharge is provided as a rough approximation only. It will differ depending on the usage conditions, etc.
*4 Maximum flow rate is a value indicating the pump capacity. We recommend selecting a size that allows some leeway, taking into account the impact on the life span of the diaphragm.
Dimentional drawing
Performance curve
Downloads
Parts List
View Parts List and Exploded View NDP-50-E
Click to open the parts list page.
View Parts List and Exploded View NDP-500-E